Difference between revisions of "UW-Stout/Nonionic Detergent SP22"

From SGD-Wiki
Jump to: navigation, search
Line 9: Line 9:
 
• Wild-type yeast in 2x synthetic complete media at an OD600 of 0.1-0.2
 
• Wild-type yeast in 2x synthetic complete media at an OD600 of 0.1-0.2
  
3. Equipment:
+
3.Equipment:
 
• Molecular Devices SpectraMax Plus 384 Microplate Reader
 
• Molecular Devices SpectraMax Plus 384 Microplate Reader
  

Revision as of 09:46, 4 May 2022

Pilot experiment: Testing NLS effect on WT yeast cells growth

1. Introduction: In this experiment, we will be testing the effect of N-Lauroylsarcosine on the speed of growth of wild type yeast cells. Our objective is to find the concentration of NLS needed to affect the yeast cell growth without killing them all.

2.Materials: • (NLS) N-Lauroylsarcosine sodium salt >=94% • Corning COSTAR 96-well clear flat-bottom assay plate • Wild-type yeast in 2x synthetic complete media at an OD600 of 0.1-0.2

3.Equipment: • Molecular Devices SpectraMax Plus 384 Microplate Reader

4.Procedure:

1. Make a 0.1% solution of NLS by putting 1µl of a 10% solution of NLS in 99 mL of water. This is going to give you a 100 mL solution with a 0.1 concentration of NLS. 2. Use the 0.1% solution of NLS to make 7 different concentrations of N-Lauroylsarcosine (0%, 0.001%, 0.002%, 0.005%, 0.01%, 0.02%, 0.05%). To increase solubility, temperature can be increased to 25-30°C. 3. Set up 8 wells according to following table.

Well A (0%) Well B (0.001%) Well C (0.002%) Well D (0.005%) Well E (0.01%) Well F (0.02%) Well G (0.05%) Well H (0.1%)
Yeast culture 50µl 50µl 50µl 50µl 50µl 50µl 50µl 50µl
0.1% solution of NLS X 0.5µl 1.0µl 2.5µl 5.0µl 10µl 25µl 50µl
Deionized water 50µl 49.5µl 49µl 47.5µl 45µl 40µl 25µl X


4. Set up the plate reader as follows:

Temperature: 30°C Mode: Kinetic Wavelength: 600 nm Interval: 5 minutes Total run time: 24 hours Shake before read: 30 seconds

5. Transfer the assay plate to the reader and read for 24 hours. Notes • Results:

-Here is the graph obtained after following the procedure above and putting it in the plate reader for 24 hours:

Growth rate of a WT yeast cell when mixed with different concentration of NLS.png


-Under is a graph with a Y axis scale set to logarithmic so we can find the doubling-time of the WT yeast cell in well B,D,E,F when mixed with a 0.001% solution of NLS:


Growth rate of WT yeast cell with 0.001% NLS (Logarithmic) .png


Doubling time of Well B, D, E, F

-Td (Well B)= 547 minutes -Td (Well D) = 1442 minutes -Td (Well E) = 1086 minutes -Td (Well F) = 496 minutes -Td (average) = 893 minutes


Doubling Time for Well A (0% NLS) and Well C (0.002% NLS):

-Td (Well A) = 302 minutes -Td (Well C) = 10 570 minutes


• Analysis and Conclusions:

-According to the graph above and the doubling time found, we noticed that in well A (with only water), the growth of the WT yeast cell was significant with a doubling time of 302 minutes. In Well C (0,002% NLS), practically no growth occurred with having a doubling time of 10 570 minutes. Following this information, we concluded that 0,002% NLS was too concentrated for any growth to occur.

-Furthermore, after seeing that well B’s growth rate graph and its doubling time (893 minutes) were situated in between A’s and C’s, we concluded that 0,001% was the concentration we were going to use.

-Important to note: the concentration used need to be divided by 2 because out of the 100µl solution, 50µl is yeast cell so it dilutes the previous dilution. With that being said, we are technically using 0,0005% NLS.