Difference between revisions of "UW-Stout/Heat Shock"
Line 3: | Line 3: | ||
'''Materials''' | '''Materials''' | ||
− | Yeast genes of each group | + | # Yeast genes of each group |
− | Hot Water bath | + | # Hot Water bath |
− | Water bath tube holders | + | # Water bath tube holders |
'''Preliminaries''' | '''Preliminaries''' |
Revision as of 06:24, 30 April 2019
Preliminaries
None
Materials
- Yeast genes of each group
- Hot Water bath
- Water bath tube holders
Preliminaries
None
Calibration Materials
- Wild type yeast (we used BY4735)
- Hot water bath
- Water bath tube holders
- Assay plate
Calibration Procedure
- Set the water bath to 37 degrees Celsius and wait for it to heat up
- Once it is set at the correct temperature, place the yeast samples into it (100-micro-liter samples)
- Take samples are 0 minutes, 15, 30, 45, an hour, an hour 15 minutes, and an hour and a half
- After the hot water bath, pipette yeast out and place into an assay plate
Knockout Materials
- Knocked out yeast gene sample(s)
- Hot water bath
- Water bath tube holders
- Assay plate
Knockout Procedure Day 1
- Set the water bath to 37 degrees Celsius and wait for it to heat up
- Pick a time slot from the original calibration in order to test
- Put all yeast sample(s) in for specified time and wait
- After time take yeast sample(s) out and put into the assay plate
Knockout Procedure Day 2
- Set the water bath to 37 degrees Celsius and wait for it to heat up
- Pick a time slot from the original calibration in order to test (that is different from day 1)
- Put all yeast sample(s) in for specified time and wait
- After time take yeast sample(s) out and put into the assay plate